Normac NR-85LVHS Parts "A" and  "B"

Product Description: A 100% solids, Flame Retardant Heated Plural Component Sprayable Urethane System.

Material: Stripped TDI Polyether/PTMEG Polyol.
(Less than 0.1% free isocyanate).

Mix Ratio:        Part "A"    Part "B"
By Weight:              100       83.33       
By Volume:           100        100

Package Sizes:  Packaged/Sold by Weight

Kit            Part "A"    Part "B"
  44.36 kg. (A+B)       18.0 kg.      15.0 kg.
500.00 kg. (A+B)     409.094kg.    341.0 kg.

Application Life:
Less than one minute @ 65oC (150oF)

Tack Free:    5 - 10 min. @ 21oC (70oF)

Print Free:    10 - 20 min. @ 21oC (70oF)

Hardness:    80 + 5  Shore A

Bashore Resilience:    N.A.

Impact Resistance:
Greater than 160 inch - pounds (ASTM D2794)

Tear Strength:    111 pli (ASTM D-470)
        Die C@ 321lbs psi

Tensile Strength: 2850 psi (ASTM D412)

Elongation: 435% (ASTM D412)

Abrasion Resistance:  0.093 grams weight loss per 1000 cycles, H18 wheel, at 1000 gms. (ASTM D1-044)

Operating Temperature:  -56oC (-70oF) to 93oC (200oF)

Fungus Resistance:    Non-nutrient
 
Weight of Cured Coating: 29 gm./m2 @ 25 microns 0.60 lbs. per 100 ft.2 at .001" thick

Modulus 100%: 560 psi (ASTM D412)

Ultimate Cure:    5 days at 21oC (70oF)

Recoat Times:    Continuous: Maximum 2 hours

Mixed Solids Content: 100%

Flash Point:  None, Normac NR-85LVHS Part "A" and "B" are both non-flammable in shipping, storage and application.

Application:   Normac NR-85LVHS is applied thru heated plural component equipment.  The spray gun is both impingement and static mix with an adaptor to fit Graco RAC IV spray tips to suit all types of applications.  This system uses air pressure to purge the mix chambers and tips.  No solvent is required during application.  Typical operating temperatures are approximately 65oC (150oF).  Air requirements for the main pumps is 100 lbs.

Surface Preparations and Primers:  Standard surface preparation procedures such as grit blasting to near white metal or acid etching concrete is required for good mechanical bonding of the NR-85LVHS sprayable urethane system. See "Normac Surface Preparation Guide for Urethane Coatings".

Primers:
NR-9500: A two component, single coat air curing solvent based primer used over NR-9600.
NR-9600: A two component wash primer base for NR-9500.
EP-100: A two component 199% solids primer for concrete.
Refer to specific primer/adhesive data sheets.

Theoretical Coverage:
34 m2 @ 25 microns/kg. DFT (166 ft2/lb. at .001"DFT).

   