Normac NR-70LVHS

Product Description: A 100% solids Heated Plural Component Sprayable Urethane System.

Material: Stripped TDI Polyether.
(Less than 0.1% free isocyanate).

Mix Ratio:         Part "A"    Part "B"
By Weight:              100       46.0       
By Volume:              100       50.0

Package Sizes:  Packaged/Sold by Weight

Kit                           Part "A"      Part "B"
  30.00 kg. (A+B)       20.8 kg.        9.60 kg.
597.14 kg. (A+B)     409.0 kg.    188.14 kg.

Application Life: Less than one minute @ 65oC (150oF)

Tack Free: 5 - 10 min. @ 21oC (70oF)

Print Free: 10 - 20 min. @ 21oC (70oF)

Hardness: 70 +/- 5  Shore A

Bashore Resilience: N.A.

Impact Resistance: Greater than 160 inch - pounds (ASTM D2794)

Tear Strength: 68 pli (ASTM D-470) Die C@ 256lbs

Tensile Strength: 2000 psi (ASTM D412)

Elongation: 300% (ASTM D412)

Abrasion Resistance:  0.047 grams weight loss per 1000 cycles, H18 wheel, at 1000 gms. (ASTM D-1044)

Operating Temperature:  -56oC (-70oF) to 93oC (200oF)

Fungus Resistance: Non-nutrient

Weight of Cured Coating: 29 gm./m2 @ 25 microns 0.60 lbs. per 100 ft.2 at .001" thick

Modulus 100%: 620 psi (ASTM D412)

Ultimate Cure: 5 days at 21oC (70oF)

Recoat Times: Continuous: Maximum 2 hours

Mixed Solids Content: 100%

Flash Point: None, Normac NR-70LVHS Part "A" and "B" are both non-flammable in shipping, storage and application.

Application:   Normac NR-70LVHS is applied thru heated plural component equipment.  The spray gun is both impingement and static mix with an adaptor to fit Graco RAC IV spray tips to suit all types of applications.  This system uses air pressure to purge the mix chambers and tips.  No solvent is required during application.  Typical operating temperatures are approximately 65oC (150oF).  Air requirements for the main pumps is 100 lbs.

Surface Preparations and Primers:  Standard surface preparation procedures such as grit blasting to near white metal or acid etching concrete is required for good mechanical bonding of the NR-70LVHS sprayable urethane system. See "Normac Surface Preparation Guide for Urethane Coatings".

Primers:
NR-9500: A two component, single coat air curing solvent based primer.
NR-9600: A two component wash primer base for NR-9500.
900R:  A two component, air curing rubber based primer.
EP-100: A two component 100% solids primer for concrete.
Refer to specific primer/adhesive data sheets.

Theoretical Coverage:
34 m2 @ 25 microns/kg. DFT (166 ft2/lb. at .001" DFT).

   